- Lasers
- Laser Parts
- Laser Machines
- Instrument & Measurement
- Optics & Crystals
- Fiber, Fiber Optics & Probes
- Acousto- & Electro-optic Devices
- Laser Accessories
LATEST NEWS
Laser Pump Chamber
- Stainless steel or non-metal body
- High UV absorbing flow tubes
- Crystal & lamp water jackets
- Gold-coated elliptical pump cavity or alumina diffuse reflector
PRODUCT DESCRIPTION
Single or duallamp high-efficiency laser pump chambers can accommodate laser rods of 3 to10mmin diameter and up to180mmin length.
A laser pumpchamber consists of
* Stainless steel or non-metal body* Gold-coated ellipticalpumpcavityoralumina diffuse reflector(ceramic reflector)
* Series or parallel cooling path
* High UV absorbing flow tubes
* Crystal& lamp waterjackets
* Parallel lamptrigger connectoror series trigger
* Coolant fitting
* O-rings
* Lamp (option)
* Laser rod (option)
1. Gold-coated laser pump chambers
1) single-lamp pump chambers
A: Model number: BPQJA-xxx
BPQJA: single lamp and single rod gold pump chambers.
xxx: the length of the gold reflector or the arclength of the lamp.
Typical Pump Chambers:
Model |
Length of reflector |
Overall length |
YAG rod length |
Typical lamp |
BPQJA-100 |
100mm |
190mm |
≥110mm |
NL9764,ST5166,ST5171 |
BPQJA-110 |
110mm |
200mm |
≥120mm |
|
BPQJA-120 |
120mm |
210mm |
≥130mm |
ST5647 |
BPQJA-130 |
130mm |
220mm |
≥140mm |
|
Remark: suitableto YAG rods of 3-9mmin diameterand lamps of 4-10mminoutside diameter.
B: Model number: BPQJA-xxxCD
BPQJA: single lamp and single rod gold pump chambers.
xxx: the length of the gold reflector or the arclength of the lamp.
CD: CD series chamber
Typical Pump Chambers:
Model |
BPQJA-120CD |
BPQJA-130CD |
BPQJA-140CD |
Shape of reflector |
gold coated ellipse |
||
Length of reflector,L1 |
120mm |
130mm |
140mm |
Width of chamber, D1 |
56mm |
||
Width of base,D2 |
76mm |
||
Length of base,L |
236mm |
246mm |
256mm |
Overall height,H1 |
61mm |
||
Central height,H2 |
42mm |
||
Hole dia. for lamp |
≤Φ8.5 |
||
Hole dia. for YAG rod |
≤Φ8.5 |
||
Mounting holes spacing (L×W) |
144×66mm |
||
Max. input electric power: |
≤5000W |
||
Recommended lamp dimension |
Φ8×120×270mm |
Φ8×130×280mm |
Φ8×140×290mm |
Flow rate (l/min) |
25l/min |
||
Water cooling input location |
Side or base |
Remark:Suitable rod diameter is3-5mm.
2) Dual-lamppump chambers
Model number: BPQJB-xxx
BPQJB:dual lamp and single rod gold pump chambers.
xxx: the length of the gold reflector or the arclength of the lamp.
Typical Pump Chambers:
Model |
Length of reflector |
Overall length |
YAG rod length |
Typical lamp |
BPQJB-130 |
130mm |
228mm |
≥140mm |
|
BPQJB-140 |
140mm |
238mm |
≥150mm |
|
BPQJB-150 |
150mm |
248mm |
≥160mm |
NL5121,NL9762 |
BPQJB-170 |
170mm |
268mm |
≥180mm |
|
Remark: suitable to YAG rods of 3-9mmin diameter and lamps of 4-10mmin outside diameter.
3) Highpower Dual-lamp pump chambers
Model number: CHBA-xxx-yy-xxx
BPQJB:Dual lamp and single rod gold pump chambers.
xxx: Reflector length
yy: Cooling method, DC for Dry Cooling or WC for WaterCooling
zz: Average power, 500 & 650W are available
Dry cooling, Laser head fitted withYAG rod and two flashlamps with flying leads. This laser head is designed tooperate with a dry gold cavity reflector similar to that of theTrumpf laser head.
Laser Head fitted with YAG rod andtwo flashlamps. These are fully immersed in DI water. This laser head isdesigned to operate with clean DI water . The laser head is similar tothat of the Rofin Baasel 500W unit. The applications are laser cutting and laser welding.
Specifications:
Model |
Yag Rod (mm) |
Lamp |
configuration |
Dimension (WxLxH, mm) |
SCHBA-180-DC-500 |
Dia8x190 |
ST180DC |
Dry cooling, Laser head fitted with YAG rod and two flashlamps with flying leads. |
80 x 265 x 74 |
SCHBA-180-DC-650 |
Dia8x190 |
ST180DC |
Dry cooling, Laser head fitted with YAG rod and two flashlamps with flying leads. |
80 x 265 x 74 |
SHBA-180-DC |
Dia8x190 |
ST180DC |
Dry cooling laser head but less YAG rod but includes two flashlamps. |
80 x 265 x 74 |
SCHBA-180-WC-500 |
Dia8x190 |
ST180 |
Laser Head fitted with YAG rod and two flashlamps. These are fully immersed in DI water. |
104 x 334 x 74 |
SCHBA-180-WC-650 |
Dia8x190 |
ST180 |
Laser Head fitted with YAG rod and two flashlamps. These are fully immersed in DI water. |
104 x 334 x 74 |
SHBA-180-WC |
Dia8x190 |
ST180 |
Water cooling laser head but less YAG rod but includes two flashlamps . |
104 x 334 x 74 |
2. Ceramic laser pump chambers
Model number: BPQT-xxxD
BPQT:ceramic pump chambers.
xxx: the length of the ceramic reflector.
D: D means dual lamp chamber and no D meanssingle lamp chamber.
(1) single lamp and single rod
Model: BPQT-97Ceramic reflector TCT97 used
Matchable YAG rods:f(3-7)x120mmor longer
Matchable lamps: ST5166, NL9764 (maximum OD is8mm.)
Suitable for 50W to 100W YAG lasers
Dimension: 240x55x40mm
(2) single lamp and single rod
Model: BPQT-117Ceramic reflector TCT117 used
Matchable YAG rods:f(3-7)x140mmor longer
Matchable lamps: ST256 (maximum OD is8mm, overall length >270mm.)
Suitable for 80W to 150W YAG lasers
Dimension: 260x55x40mm
(3) dual-lampcavity (double lamp and single rod)
Model: BPQT-130DCeramic reflector BAB-350
Matchable YAG rods: dia. 3-8mm, length140mmor longer
Matchable lamps: arc length 130-140mmor longer & OAL270mm.
Suitable for 250W to 300W YAG lasers
(4) dual-lamp pump chamber (2pcs lamps and one rod)
Model: BPQT-150DWCeramic reflector BAB492
Matchable YAG rods:f(3-8)x160mmor longer
Matchable lamps: lamps with the arc length of around150mmand overall length of310mm, typicallySTK-8x150x310-5x10,STX-8x150x310-5x10, NL9762.
Suitablefor 450W to 500W YAG lasers
(5) dual-lamp pump chamber (2pcs lamps and one rod)
Model: BPQT-170DWCeramic reflector BAB497
Matchable YAG rods:f(3-8)x180mmor longer
Matchable lamps: lamps with the arc length of around170mmand overall length of330mm, typicallySTK-8x170x330-5x10,STX-8x170x330-5x10.
Suitablefor 500W to 600W YAG lasers
Note:
1. External mechanical dimensions can beredesignedto meetcustomer's exact requirements;
2. Laser rods customized to your exact requirements available uponrequest.Please tell us thediameter of the YAG rod when placing the order.
3. Detailed drawing and dimensions can befound from our websites.
5. If you want us to design a specific pumpchamber, you need to tell us the specifications of YAG rod and lamps asfollows:
1) YAGrod: diameter and length;
2) Lamp,dimension of arc length, outside diameter, overall length, end type (basediameter and length) etc or model number. Please refer to our websites for moredetails of lamps.
Ordering Information:
* Whenplacing the order for the pump chamber, the buyer should tell us the dimensionsof the rod and the lamp or lamp’s model so that we can give right O-rings.* lampconnectors are not included in the pump chamber.
* Thelamp and rod are not integrated into the pump chamber for convenient shipping.If integration is needed, the buyer takes its risk of the rod and lamp to bebroken during the shipping. In general, separate package of lamp, rod and pumpchamber are safer.
Combination of Typical Pump Chambers
Model |
Reflector |
YAG rod |
Lamp model |
Typical laser power |
BPQT-97 |
BAB192 |
4x120mm |
CW: STK-8x100x256-5x10 ST5166 Pulsed: STX-8x100x256-5x10 NL9764 |
50-70W |
BPQT-117 |
BAB330 |
4x140mm |
CW: STK-8x125x270-5x10 ST256 Pulsed: STX-8x125x270-5x10 |
80-150W |
BPQT-130DW |
BAB350 |
6x140mm |
CW: STK-8x130x285-5x10 Pulsed: STX-8x130x285-5x10 |
250-300W |
BPQT-150DW |
BAB492 |
8x160mm |
CW: STK-8x150x310-5x10 Pulsed: STX-8x150x310-5x10 NL9762 |
450-500W |
BPQT-170DW |
BAB497 |
8x180mm |
CW: STK-8x170x330-5x10 Pulsed: STX-8x170x330-5x10 |
500-600W |
Remark: For a same pumpchamber, larger rod will output much higher laser power but laser beam qualitybecomes worse.
How to Select a Pump Chamber
Themost important parameter to select a pump chamber is the average power you wantfrom the pump chamber. Once you finalise the power you want, then pleaseremember the following points in mind:
* (reflector length) = (rod length)–10mmfor a gold chamber.* (arclength of lamp) = (reflector length)
* (overalllength of lamp) = (arc length) +160mm(here160mmis thenumber according to our experience)
* (internaldiameter of lamp) = (rod diameter)
* For STK andSTX series lamps, glass tube’s thickness is1mm.
* (BASEdiameter) = (outside diameter) –2.5mm.In most cases, it is 3, 3.5, 4, 4.5, 5,5.5 etc